Doosan Diagnostic Tool UVIM Support Doosan Excavators High Quality
NOTE:Periodically the mesh strainer must be cleaned and the paper element must be replaced.
1. Loosen the bolts and separate the mesh strainer.
2. Pull out the mesh strainer.
2023.07 Doosan DMS-5 Data Monitoring System Diagnostic Software
3. Soak the mesh strainer in diesel oil and wipe the outside with a non-metallic brush.
4. Soak the mesh strainer again in new
dieseloil and take it out.
5. Blowing the compressed air inside the mesh strainer.
6. Repeat items 3 through 5, 4-5 times.
7. Assemble in the reverse order of disas sembly.